Applications
Used to provide insulation protection for cable terminal , load-break switches , power circuit breakers , etc.
Features
Anti-tracking insulation tube
Tracking resistant:UV resistant
Halogen free
Minimum fully shrink temperature : 125℃
Shrink ratio : 3:1
Standard color : Red
Technical Data
Dimensions
Test ltems
Method of Test
Test Requirements
Tensile strength
ASTM D 2671
10MPa min.
Ultimate elongation
ASTM D 2671
200% min
Tensile strength after Aging at 150°C for 168hrs
ASTM D 2671
10MPa min.
Ultimate elongation after Aging at 150℃ for 168hrs
ASTM D 2671
100% min.
Heat shock at 200°C/30min
ASTM D 2671
No cracking, dropping
Density
ASTM D 792
1.2~1.3g/cm3
Dielectric strength
IEC 60243
10kV/mm(2.5mm)min.
Volume resistivity
ASTM D 2671
1012Ω.cm min.
Low temperature flexibility
ASTM D 2671 Proc.C
No cracking
Permittivity
ASTM D 150
3(nom.)
Tracking resistance
ASTM D 2303
No tracking
DM-ATH | As supplied | After recovered | Standard | DM-ATH | As supplied | After recovered | Standard | ||
Size(mm) | D(Min mm) | d(Max min. | t(Min.mm) | Length | Size(mm) | D(Min mm) | d(Max min.) | t(Min.mm) | Length |
19/6 | 19 | 6 | 25 |
30m/roll or
0.5-1.5m
|
65/21 | 65 | 21 | 3.3 |
30m/roll or
0.5-1.5m
|
30/10 | 30 | 10 | 2.9 | 75/25 | 93 | 25 | 3.5 | ||
38/12 | 38 | 12 | 2.9 | 85/29 | 125 | 29 | 3.5 | ||
40/16 | 40 | 16 | 25 | 100/40 | 118 | 40 | 4 | ||
49/16 | 49 | 16 | 2.9 | 130/50 | 155 | 50 | 4 | ||
55/18 | 55 | 90 | 2.9 | ||||||
DM-ATHA (Cut length tubing) | |||||||||
38/16 | 30 | 18 | 2.9 | 1.0-1.5 | 65/21 | 65 | 21 | 3.3 | 1.0-1.5 |
40/12 | 40 | 12 | 2.9 | 75/25 | 75 | 25 | 3.5 | ||
43/14 | 43 | 14 | 25 | 85/29 | 85 | 29 | 3.5 | ||
49/16 | 49 | 16 | 2.9 | 100/40 | 100 | 40 | 4.0 | ||
55/18 | 55 | 18 | 2.9 | 130/50 | 130 | 50 | 4.0 |